B braun syringe pump perfusor compact manual


















The error code of the control microprocessor can be queried with the F button. Please state both error codes if you have any questions. Acknowledge alarm and switch device off. Interface cable Page 22 [Version 2. Page 23 To uninstall the service program incl.

Configuration 1. Select the language and interface with the Connect service cable Fig. Enter the user number 0 upon query. Page 26 Is the service cable connection okay? Is the MFC correctly connected? Then: Press the ON-key on the Perfusor compact until the symbols disappear.. Is syringe selection set to "free type", but "free type" Version number of service program [Version 5. Note Successful transfer to the progam of calibration data is displayed as follows in the footer: [Version 5.

Length calibration F5 The position of the prealarm light barriers and the drive end is determined by length calibration. Page 30 Table and free type Fig. Page 31 Fig. The syringe types are numbered in sequence using the syringe index [Version 2. Modes Menu Page 32 Service Program Note Please pay attention to the notes given with the staff call cable.

CAUTION The pressure stage which was set last and the syringe type that was selected last are overwritten with the pump settings when the unit is switched off. Switch on unit. Start the Service Program. Page 34 Service Program Alarm Tone 1. Insert syringe and confirm or select , e. OPS 50 ml. Enter rate and actuate the Start button to start delivery.

Open syringe holder, an alarm is triggered. Compare the alarm tone with the settings: [Version 5. Check whether the free type was marked on the unit please see syringe table. Transfer data to device via menu item F7. Page Fundamental Repair Information If the battery pack is used, then the device is to be switched on with line connection. Note Defective batteries must be disposed of according to the regulations, e. Page 40 Unit Elements Designation Ord.

Small parts kit for 5 units Page 41 Unit Elements Open unit 1. Loosen 5 screws from the bottom. Open housing carefully, then 3. Pull off the ribbon cable from the E-Module and the connection cable from the motor. Hold the white board holder on the E-Module when disconnecting! Page 42 Unit Elements Fig. Close unit in reverse order of opening.

Note Do not squeeze motor cable. Instructions for use, complete Language: German Page Syringe Holder Unit Elements 4.

Syringe holder, complete Battery compartment cover Screw out screwed split rivet. Page A-Module Unit Elements 4. A-Module, complete, with board, MFC and buzzer. Page Ls-Clip Unit Elements 4. Page E-Module Unit Elements 4. This is an expansion of a previous recall, initiated by B. Braun in January, , due to the potential for breakage of the anti free flow clip catch located inside the infusion pump door.

Breakage may occur when the IV set anti free flow clip catch. Measuring just 9' x 6' and weighing only 3 pounds, the compact and lightweight design of the Perfusor Space Syringe Pump allows easy transport and flexibility in crowded care settings.

The easy-to-learn and easy-to-program system includes built-in error reduction software and a medication library accommodating both hard and soft limits, large navigational arrows and a screen that remains legible in any light condition.

Quality Management B. This certification also includes maintenance and service. The unit has the CE label. Original test equipment can be calibrated at the works of B. Further information is available upon request. Setting Off Additional notes and warnings are set off as follows Page 9: Technical Training Entry for Technical Training Application for a technical training course must be made via the responsible representative.

Braun subsidary. Page Physical Construction 1 - 4 System Overview Physical Construction The Perfusor compact is a compact, stacking, portable and lightweight syringe pump which is used for precise dosing of small to high volumes of fluids in infusion and alimentary therapies. The standard delivery rate range is 0. Page Function System Overview Function The electronics of the Perfusor compact consists of the following components: 1.

A-Module with MFC board as the central power supply and interface 2. E-Module as operating and control unit 3. Drive unit, consisting of drive board with the complete sensor technology, light Unit connecting lead V Page Approved Software Versions 2 - 6 Software Approved Software Versions The software and hardware revision level is displayed on the LC- Position 1 2 3 4 5 6 7 8 9 display when the unit is switched on.

The characters on the display must correspond with the indication on the instructions Digit P L A A 0 0 7 2 1 for use. Page Error Messages And Alarms Software Error Messages and Alarms In case of a unit malfunction a continuous signal is activated, and the function processor displays an alarm and an error code. The error code of the control microprocessor can be queried with the F button.

Please state both error codes if you have any questions. Acknowledge alarm and switch device off. Interface cable Page 22 [Version 2. Page 23 To uninstall the service program incl. Configuration 1. Select the language and interface with the Connect service cable Fig.

Enter the user number 0 upon query. Page 26 Is the service cable connection okay? Is the MFC correctly connected? Then: Press the ON-key on the Perfusor compact until the symbols disappear.. Is syringe selection set to "free type", but "free type" Version number of service program [Version 5. Note Successful transfer to the progam of calibration data is displayed as follows in the footer: [Version 5. Length calibration F5 The position of the prealarm light barriers and the drive end is determined by length calibration.

Page 30 Table and free type Fig. Page 31 Fig. The syringe types are numbered in sequence using the syringe index [Version 2. Modes Menu Page 32 Service Program Note Please pay attention to the notes given with the staff call cable. CAUTION The pressure stage which was set last and the syringe type that was selected last are overwritten with the pump settings when the unit is switched off. Switch on unit. Start the Service Program. Page 34 Service Program Alarm Tone 1.

Insert syringe and confirm or select , e. OPS 50 ml. Enter rate and actuate the Start button to start delivery. Open syringe holder, an alarm is triggered. Compare the alarm tone with the settings: [Version 5. Check whether the free type was marked on the unit please see syringe table.

Transfer data to device via menu item F7. Page Fundamental Repair Information If the battery pack is used, then the device is to be switched on with line connection. Note Defective batteries must be disposed of according to the regulations, e. Page 40 Unit Elements Designation Ord.